Toxic Gas Sensor

MQ-E3-H2S Electrochemical H2S Sensor

Application:

For detecting H2S in industry, mine, or environmental protection field

Product characteristics:

Be stable
Anti-jamming High accuracy
High sensitivity
Wide linear range
Excellent repeatability
Low power consumption

1. Description

MQ-E3-H2S is the sensor of fixed potential electrolysis type. By redox reaction, H2S and Orelease charge and form the current. The value of current is proportional to the concentration of H2S and follow the Faradays Law. By testing the value of current, the concentration of H2S is known.

2. Application

Widely used in industry, mine, or environmental protection field for detecting H2S.

3. Appearance and dimension

 

4.Technical specification

projectparameter
Detected gashydrothion (H2S)
range0- 100ppm
Maximum measurement range500ppm
sensitivity(0.8±0.15)uA/ppm
resolution ratio0.1ppm
Response time (T90)<30s
Load Resistanc10Ω
Stability (/ month)<2﹪
Output linearitylinear
zero drift (-20℃~40℃)≤0.2ppm
temperature range-20℃~50℃
Humidity range15﹪~90﹪RH
pressure rangeStandard atmospheric pressure is±10
life span2 years

5.Sensor Characterization


6.Precautions

 Soldering is prohibited during installation;

 Aging time should be no less than 48 hours before use;

 Pins must not be broken or bent;

 Electrolyte leakage will cause damage, please do not disassemble the sensor at will;

 Sensors should avoid contact with organic solvents (including silicone rubber and other adhesives), coatings, chemicals, oils and high-concentration gases;

 All electrochemical sensors should not be completely encapsulated with resin materials, nor should they be immersed in an oxygen-free environment for a long time, otherwise the performance of the sensor will be damaged;

 All electrochemical sensors should not be used in an environment containing corrosive gases for a long time, as corrosive gases will damage the sensor;

 When measuring the zero point of gas, it must be done in a clean atmosphere;

 When testing and applying the sensor, vertical air intake from the front should be avoided;

 The air intake hole of the sensor must not be blocked or contaminated;

 The sensor must not be subjected to excessive impact or vibration;

 Do not use if the shell is damaged or deformed;

 The recovery time is long when used in an environment with high concentration of the measured gas;

 The working electrode and the comparison electrode should be in a short-circuit state when the sensor is stored;

 It is forbidden to use hot melt adhesive or adhesive with curing temperature higher than 80℃ to encapsulate the sensor;

 It is forbidden to store and use in high concentration alkaline gas for a long time.