Toxic Gas Sensor

MQ-E3-NO2 Electrochemical NO2 Sensor

for industry gas monitoring

Application:

For detecting NO2 in industry or environmental protection field

Product characteristics:

Be stable
Anti-jamming
High accuracy
High sensitivity
Wide linear range
Excellent repeatability
Low power consumption

1. Description

MQ-E3-NO2 is the sensor of fixed potential electrolysis type. By redox reaction, NO2 and Orelease charge and form the current. The value of current is proportional to the concentration of NO2 and follow the Faradays Law. By testing the value of current, the concentration of NO2 is known.

2. Application

Widely used in industry or environmental protection field for detecting NO2.

3. Appearance and dimension

 

4. Technical specifications

projectparameter
tracer gasNitrogen dioxide (NO2)
range0~20ppm
Maximum measurement limit150ppm
sensitivity(0.78±0.42)µA/ppm
resolution ratio0.1ppm
Response time (T90)<25S
Load Resistance(recommended)10Ω
bias voltage0mV
repetitiveness<2. Output value
Stability (/ month)<2﹪
Output linearitylinear
Zero-point drift (-20℃ ~40℃)0.2ppm
temperature range-20℃~50℃
Humidity range15﹪~90﹪RH
pressure limitStandard atmospheric pressure is ± 10
life length2 years (In Air)


5.Basic Circuit



6.Sensor Characterization



7.Precautions


 Soldering is prohibited during installation;

 The pins must not be broken or bent;

 The aging time before use must be no less than 48 hours;

 Electrolyte leakage may cause damage, so please do not disassemble the sensor at will;

 The sensor should avoid contact with organic solvents (including silicone rubber and other adhesives), paints, pharmaceuticals, fuel oils and high-concentration gases;

 All electrochemical sensors should not be completely encapsulated with resin materials, nor immersed in an oxygen-free environment, otherwise the performance of the sensor will be damaged;

 All electrochemical sensors should not be used in an environment containing corrosive gases for a long time, as corrosive gases can damage the sensor;

 When measuring the zero point of gas, it must be done in a clean atmosphere;

 When testing and applying the sensor, vertical air intake from the front must be avoided;

 The air intake surface of the sensor must not be blocked or contaminated;

 The waterproof and breathable membrane above the sensor must not be opened or damaged;

 The sensor should not be subjected to excessive impact or vibration;

 Do not use it if the shell is damaged or deformed;

 It takes a long time to recover to the initial state after long-term use in a high-concentration gas environment;

 When storing the sensor, the working electrode and the reference electrode should be in an open circuit state;

 It is forbidden to encapsulate the sensor with hot melt adhesive or sealant with a curing temperature higher than 80℃;

 It is forbidden to store and use the sensor in high concentration alkaline gas for a long time